Direct Antiglobulin Test (DAT)
Additional Codes
Epic# -
LAB274
Cerner name(s):
- Direct Antiglobulin Test Poly
- DAT Poly
- B DAT Poly
Alias:
- Direct Coombs
Performing Lab(s)
Memorial-Belleville & Memorial-Shiloh
Methodology
MTS gel or manual tube
Specimen Requirement (s)
Specimen Type: whole blood (WB)
Container/Tube: Pink (K2EDTA) top (full microtainer is acceptable)
Specimen Volume: Full tube
Specimen Minimum Volume: 5 mL WB (3 mL for child; full microtainer for infant)
Collection Instructions: Must be labeled with lab (barcode) label.
Day(s)/Shift(s) Test Set Up and Turnaround Time
Sunday through Saturday
Hours: 24 hours
Turnaround Time:
STAT: 45 minutes
Routine: less than 1 hours from receipt.
Transport and Stability
Transport temperature: Ambient to lab
Analyte Stability:
Ambient: 4 hours
Refrigerated: 72 hours
Frozen: NA
Reference Values
Polyspecific DAT: Negative
IgG DAT: Negative
Complement (C3) DAT: Negative
CPT/LOINC Codes
86880 (per phase of testing)
Additional Information
This test uses polyspecific AHG for testing.
- If negative, no further testing is performed.
- If positive, IgG and complement will be tested.
- An eluate will only be ordered and sent to the American Red Cross for testing if one of the following apply:
- The patient has been transfused with an RBC unit in the past 21 days.
- The patient has a newly identified alloantibody
- The patient's history is unknown.
- An eluate will only be ordered and sent to the American Red Cross for testing if one of the following apply: